Search In this Thesis
   Search In this Thesis  
العنوان
Clinical evaluation between Titanium miniplates and Biodegradable Poly-L-Lactide miniplates in treatment of mandibular angle Fractures
الناشر
Ain-Shams University.Faculty of Dentistry.the Oral and Maxillofacial Surgery department,
المؤلف
El ganzoury,Mohammed Abbass.
تاريخ النشر
2007 .
عدد الصفحات
p90.
الفهرس
Only 14 pages are availabe for public view

from 118

from 118

Abstract

In this study, we compared between the resorbable and titanium miniplates clinically and radiographically in the mandibular angle fractures. The present study was conducted on eleven adult patients consisted of eight males and three females, their age ranged between sixteen and twenty six years. The patients were selected from the out patient clinic of Oral and Maxillofacial Surgery Department, Faculty of Dentistry, Ain Shams University.
Patients were divided randomly into two groups:
In group I, the biodegradable bone plate system was used to fix the mandibular angle fracture. However, in group II, the titanium miniplate system was used to fix the mandibular angle fracture and all the patients were evaluated clinically and radiographically by OPG and PA views immediate, one month, three months and six months postoperative.