Search In this Thesis
   Search In this Thesis  
العنوان
Clinical Evaluation of Single versus
Two Implants Retaining Mandibular
Complete Overdentures :
المؤلف
Sobaih, Hany Mohamed.
هيئة الاعداد
باحث / هانى محمد محمد عزت صبيح
مشرف / أمل على سويلم
مشرف / ماجدة اسماعيل رمزي
مشرف / احمد عماد فياض
الموضوع
single implant retained overdentures, two implant retained overdentures, bleeding on.
تاريخ النشر
2023.
عدد الصفحات
xi, 105, [1] P. :
اللغة
الإنجليزية
الدرجة
الدكتوراه
التخصص
Dentistry (miscellaneous)
تاريخ الإجازة
1/1/2023
مكان الإجازة
جامعة القاهرة - الفم والأسنان - Prosthodontics
الفهرس
Only 14 pages are availabe for public view

from 122

from 122

Abstract

Purpose: The aim of this study was to compare clinically between
single and two implants retaining mandibular complete overdentures as
regards bleeding on probing and the depth of peri-implant sulcus.
Subjects and Methods: Twelve completely edentulous males were
enrolled in the study and were randomly divided into two equal groups.
First group received two implants at the canine areas. Second group
received a single implant at the midline. The degree of peri-implant
inflammation was assessed using the modified Bleeding on Probing Index
and by measuring the depth of the peri-implant sulcus (probing depth).
Assessments were carried out two weeks after overdenture delivery, then
one, two and three months later to evaluate the soft tissue changes around
the implants. Mann Whitney test was used for between-group
comparison, and Friedman test was used for within group comparison.
The significance level was set at P ≤. 0.05.
Results: There was a gradual decrease in bleeding on probing and
probing depth within each group. However, this decrease was not
statistically significant. Similarly, for both parameters, there was no
statistically significant difference between both groups at all follow-up
periods.
Conclusion: One implant retained overdentures showed
comparable results to two implant retained overdentures as regards
bleeding on probing and probing depth.
Keywords: single implant retained overdentures, two implant
retained overdentures, bleeding on.