الفهرس | Only 14 pages are availabe for public view |
Abstract To introduce algorithm of monitoring IGBTs junction temperatures through the calculation of Power losses of these Semiconductors in the three half bridges and hence feed these power losses to RC Cauer Thermal Network using the Lumped Thermal Network Parameters method in estimating their node Junction Temperatures, and showing the effect of manipulating the different electrical factors such as Current, Voltages, and Modulation Index on the Junction Temperatures, Simulating different driving scenarios, and thus these parameters can be used to reduce thermal load and protect the IGBTs when monitored estimated temperatures are hitting their limits. |