Accuracy of Dental Implants inserted by Stereolithographic surgical guide using
Partial versus Complete limiting designs
in the posterior mandible:
A Split Mouth Study
المؤلف
Hussein, Wael Alaa Eldin
هيئة الاعداد
باحث / وائل علاء الدين حسين
مشرف / محمد عبد المجيد قطامش
مشرف / مصطفي محمد سيد طه
مشرف / lllllllllllll
تاريخ النشر
2020
عدد الصفحات
IV(111) P:illus
اللغة
الإنجليزية
الدرجة
ماجستير
التخصص
طب الأسنان
تاريخ الإجازة
1/1/2020
مكان الإجازة
جامعة عين شمس - كلية طب الأسنان - جراحة
الفهرس
Only 14 pages are availabe for public view

from 129

from 129

Abstract

SUMMARY
In our study accuracy of dental implants placed using partial limiting designs were compared to completely limiting designs of stereolithographic surgical guides.
Fourteen implants were placed in three patients, two males and one female. The study design was split mouth where the right side was the control side (partial limiting design) and left side was the study side (completely limiting design). In the control side only the drilling was through the stereolithographic guide sleeves (universal sleeves), where in the study side both the drilling and implant placement was through the specific sleeves in the stereolithographic guide.
The aim of this study is to assess the radiographic accuracy of implants inserted by stereolithographic surgical guides using partially versus completely limiting designs in the posterior mandible.
Once the implants were placed, immediate postoperative CBCT was obtained and the actual implant position was superimposed over the virtual planned implant sites. The deviation between both was measured as angular deviation between the long axis of both virtual and actual implants. Linear deviation was also measured coronally and apically in three-dimensions as Dx, Dy and Dz.
The mean angular deviation of the completely limiting design was 2.86° while the mean angular deviation for the partially limiting design was 4.26°. 8
The mean total coronal deviation for the completely limiting design was 1.6mm, with the Dx was 0.64mm, Dy was 0.48mm and Dz 1.25mm. The mean total coronal deviation for the partially limiting design was 1.75mm, with the Dx was 0.61mm, Dy was 0.71mm and Dz 1.42mm.
The mean total apical deviation for the completely limiting design was 1.71mm, with the Dx was 0.73mm, Dy was 0.68mm and Dz 1.25mm. The mean total coronal deviation for the partially limiting design was 1.73mm, with the Dx was 0.36mm, Dy was 0.85mm and Dz 1.38mm.
Despite the results being statistically insignificant, the completely limiting designs showed slightly better accuracy especially the angular deviation.