Abstract Medical labs discharge their waste water to the general sewarge network without treatment , these waste water contain pathogens causing diaseases(for example HCV, HBsAg). This work aimed at disinffectanting the wastewater generated from medical labs, to be safe to gdischarge in sewerage network . Our samples are collected from the waste of out patient clinic lab in certain university and the wastewater are tested for : 1-Presence of HBsAg using ELIZA Technique. 2-Presence of pathogenic bacteria. 3-The values of COD, BOD. 4-After that, the waste is treated by chemical disinffectants (Ethylalcohol, Chlorine, Formalline, Cidex, H2O2, Clorohexidine ) to disinffectante the wastewater and repeat the examination of the presence of HBsAg and pathogenic bacteria and determine the value of COD, BOD. 5-The sample is dilluted (1:1) and treated using the same previous disinffectants and is tested for presence of HBsAg.6- The steps 1-5 are repeated on other samples of wastewater of the labs . The results show : 1-No pathogenic bacteria in the wastewater of this labs. 2-The values of COD, BOD are comply with the regulations set by law 93/62. 3-The values determined of HBsAg in the untreated waste are more than the positive control used , the chemicals give different degree of effeciancy in disinffected the wastewater, but Cidex resultes show the detection of HBsAg by ELIZA was not impaired by Cidex(gltaraldehyde at1%)wich showed complee viral inactivation ,so it is the best used as a chemical disinffectants for waste inffected by virus B. |