Search In this Thesis
   Search In this Thesis  
العنوان
ELEMENTAL INVESTIGATION OF (AL-CU) ALLOYS
AND SOME GEOLOGICAL SAMPLES USING NEUTRON
ACTIVATION AND XRF ANALYSIS TECHNIQUES/
المؤلف
.Hammad, Essam Abd-Elhady Mohamed
هيئة الاعداد
باحث / Essam Abd-Elhady Mohamed Hammad
مشرف / H. M. El-Samman
مشرف / A.M.Hassan
مشرف / E.A.M.EISSA
الموضوع
Physics.
تاريخ النشر
2012 .
عدد الصفحات
700 mg :
اللغة
الإنجليزية
الدرجة
ماجستير
التخصص
الإشعاع
تاريخ الإجازة
26/11/2012
مكان الإجازة
جامعة المنوفية - كلية العلوم - Radiation Physics.
الفهرس
Only 14 pages are availabe for public view

from 86

from 86

Abstract

Neutron activation analysis (NAA) using k0 - standardization (k0 – NAA) is wellknown
method for multi-elemental analysis. The method is used to analyze different
samples belonging to different fields. In addition, X- ray fluorescence (XRF) is also used
for multi-elemental analysis. XRF complements NAA methods. Both methods were used
for investigation of some iron ores and aluminum –Cupper alloy (Al-Cu) samples.
Elemental concentration of Iron ores and Al-Cu alloy samples were determined by k0
– NAA and XRF methods. The iron ore samples were collected from Wadi Kareim and
Umm Nar sites (the Eastern desert of Egypt). Six and two samples representing the ores
of Wadi Kareim and Umm Nar, respectively altogether with the standard samples
consisting of Fe, Au , Zr and W and the certified reference sample IAEA Soil-7 were
irradiated in one of the irradiated boxes at the Second Egyptian Research Reactor (ETRR-
2). The induced activities were counted using an efficiency calibrated HPGe detector
systems. The neutron spectrum parameters a and f characterizing the neutron irradiation
position that are needed in applying k0-NAA method were determined using the
activation product of Zr , Au, Fe and W and found a @ - 0.048 ±0.002 and f @ 38±2. k0
– NAA method was applied to determine the elemental concentrations in the two iron ore
samples. The concentrations determined were found to vary erratically form one sample
to another. The results were discussed and compared with similar results in literature.
The accuracy of the k0 – NAA method was checked by determining the elemental
concentration in the IAEA-Soil 7 reference sample. The obtained results are compared
with the recommended values. Good agreements were found within 10 %.
Short time neutron activation analysis (STNAA) was carried out to determine
concentration of major elements in Al-Cu alloy samples. Three (Al-Cu) alloys samples
with different concentrations of Cu (2, 3.5 and 5 %) altogether. Au standard sample (bare
and Cd-covered) were irradiated by neutrons using the Penumatic irradiation rabid system
(PIRS) installed at the ETRR-2. The modified k0-NAA analysis method was used to
determine the major elements in the Al-Cu alloy samples without the need to determine
the neutron spectrum parameters a and f. The Al-Cu alloy samples were also, analyzed
using XRF method. Results obtained from both methods were compared and discussed.